MultiEval

SCPI Commands :

CONFigure:NIOT:MEASurement<instance>:MEValuation:FSYRange
CONFigure:NIOT:MEASurement<Instance>:MEValuation:TOUT
CONFigure:NIOT:MEASurement<Instance>:MEValuation:DMODe
CONFigure:NIOT:MEASurement<Instance>:MEValuation:MMODe
CONFigure:NIOT:MEASurement<Instance>:MEValuation:REPetition
CONFigure:NIOT:MEASurement<Instance>:MEValuation:SCONdition
CONFigure:NIOT:MEASurement<Instance>:MEValuation:MOEXception
CONFigure:NIOT:MEASurement<Instance>:MEValuation:CPRefix
CONFigure:NIOT:MEASurement<Instance>:MEValuation:CBANdwidth
CONFigure:NIOT:MEASurement<Instance>:MEValuation:PLCid
CONFigure:NIOT:MEASurement<Instance>:MEValuation:DSS
CONFigure:NIOT:MEASurement<Instance>:MEValuation:SCSPacing
CONFigure:NIOT:MEASurement<Instance>:MEValuation:NPFormat
CONFigure:NIOT:MEASurement<Instance>:MEValuation:NREPetitions
CONFigure:NIOT:MEASurement<Instance>:MEValuation:NRUNits
CONFigure:NIOT:MEASurement<Instance>:MEValuation:NSLots
class MultiEvalCls[source]

MultiEval commands group definition. 62 total commands, 8 Subgroups, 16 group commands

get_channel_bw() ChannelBw[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:CBANdwidth
value: enums.ChannelBw = driver.configure.niotMeas.multiEval.get_channel_bw()

No command help available

return:

channel_bw: No help available

get_cprefix() CyclicPrefix[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:CPRefix
value: enums.CyclicPrefix = driver.configure.niotMeas.multiEval.get_cprefix()

No command help available

return:

cyclic_prefix: No help available

get_dmode() Mode[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:DMODe
value: enums.Mode = driver.configure.niotMeas.multiEval.get_dmode()

No command help available

return:

mode: No help available

get_dss() int[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:DSS
value: int = driver.configure.niotMeas.multiEval.get_dss()

Specifies the delta sequence shift value (Δss) used to calculate the sequence shift pattern for the NPUSCH.

return:

delta_seq_shift: No help available

get_fsy_range() LowHigh[source]
# SCPI: CONFigure:NIOT:MEASurement<instance>:MEValuation:FSYRange
value: enums.LowHigh = driver.configure.niotMeas.multiEval.get_fsy_range()

Specifies the frequency synchronization range.

return:

fsr: No help available

get_mmode() MeasurementMode[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:MMODe
value: enums.MeasurementMode = driver.configure.niotMeas.multiEval.get_mmode()

Selects the measurement mode.

return:

measurement_mode: NORMal: normal mode MELMode: multi-evaluation list mode

get_mo_exception() bool[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:MOEXception
value: bool = driver.configure.niotMeas.multiEval.get_mo_exception()

Specifies whether measurement results that the CMP180 identifies as faulty or inaccurate are rejected.

return:

meas_on_exception: OFF: Faulty results are rejected ON: Results are never rejected

get_np_format() NpuschFormat[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:NPFormat
value: enums.NpuschFormat = driver.configure.niotMeas.multiEval.get_np_format()

Specifies the format of the NPUSCH.

return:

npusch_format: No help available

get_nr_units() NofRsrcUnits[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:NRUNits
value: enums.NofRsrcUnits = driver.configure.niotMeas.multiEval.get_nr_units()

Specifies the number of resource units allocated for the NPUSCH.

return:

nof_ru: No help available

get_nrepetitions() NofRepetitions[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:NREPetitions
value: enums.NofRepetitions = driver.configure.niotMeas.multiEval.get_nrepetitions()

Specifies the number of NPUSCH repetitions.

return:

nof_repetitions: Number of NPUSCH repetitions: 1, 2, 4, …, 512, 1024, 2048

get_nslots() int[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:NSLots
value: int = driver.configure.niotMeas.multiEval.get_nslots()

Configures the length of the captured sequence of slots.

return:

nof_slots: No help available

get_plc_id() int[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:PLCid
value: int = driver.configure.niotMeas.multiEval.get_plc_id()

Specifies the physical layer cell ID.

return:

phs_layer_cell_id: No help available

get_repetition() Repeat[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:REPetition
value: enums.Repeat = driver.configure.niotMeas.multiEval.get_repetition()

Specifies the repetition mode of the measurement. The repetition mode specifies whether the measurement is stopped after a single shot or repeated continuously. Use CONFigure:..:MEAS<i>:…:SCOunt to determine the number of measurement intervals per single shot.

return:

repetition: SINGleshot: Single-shot measurement CONTinuous: Continuous measurement

get_sc_spacing() SubCarrSpacing[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:SCSPacing
value: enums.SubCarrSpacing = driver.configure.niotMeas.multiEval.get_sc_spacing()

Selects the subcarrier spacing.

return:

sub_carr_spacing: 3.75 kHz or 15 kHz

get_scondition() StopCondition[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:SCONdition
value: enums.StopCondition = driver.configure.niotMeas.multiEval.get_scondition()

Qualifies whether the measurement is stopped after a failed limit check or continued. SLFail means that the measurement is stopped and reaches the RDY state when one of the results exceeds the limits.

return:

stop_condition: NONE: Continue measurement irrespective of the limit check SLFail: Stop measurement on limit failure

get_timeout() float[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:TOUT
value: float = driver.configure.niotMeas.multiEval.get_timeout()

Defines a timeout for the measurement. The timer is started when the measurement is initiated via a READ or INIT command. It is not started if the measurement is initiated manually. When the measurement has completed the first measurement cycle (first single shot) , the statistical depth is reached and the timer is reset. If the first measurement cycle has not been completed when the timer expires, the measurement is stopped. The measurement state changes to RDY. The reliability indicator is set to 1, indicating that a measurement timeout occurred. Still running READ, FETCh or CALCulate commands are completed, returning the available results. At least for some results, there are no values at all or the statistical depth has not been reached. A timeout of 0 s corresponds to an infinite measurement timeout.

return:

timeout: No help available

set_channel_bw(channel_bw: ChannelBw) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:CBANdwidth
driver.configure.niotMeas.multiEval.set_channel_bw(channel_bw = enums.ChannelBw.B200)

No command help available

param channel_bw:

No help available

set_cprefix(cyclic_prefix: CyclicPrefix) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:CPRefix
driver.configure.niotMeas.multiEval.set_cprefix(cyclic_prefix = enums.CyclicPrefix.EXTended)

No command help available

param cyclic_prefix:

No help available

set_dmode(mode: Mode) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:DMODe
driver.configure.niotMeas.multiEval.set_dmode(mode = enums.Mode.FDD)

No command help available

param mode:

No help available

set_dss(delta_seq_shift: int) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:DSS
driver.configure.niotMeas.multiEval.set_dss(delta_seq_shift = 1)

Specifies the delta sequence shift value (Δss) used to calculate the sequence shift pattern for the NPUSCH.

param delta_seq_shift:

No help available

set_fsy_range(fsr: LowHigh) None[source]
# SCPI: CONFigure:NIOT:MEASurement<instance>:MEValuation:FSYRange
driver.configure.niotMeas.multiEval.set_fsy_range(fsr = enums.LowHigh.HIGH)

Specifies the frequency synchronization range.

param fsr:

No help available

set_mmode(measurement_mode: MeasurementMode) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:MMODe
driver.configure.niotMeas.multiEval.set_mmode(measurement_mode = enums.MeasurementMode.MELMode)

Selects the measurement mode.

param measurement_mode:

NORMal: normal mode MELMode: multi-evaluation list mode

set_mo_exception(meas_on_exception: bool) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:MOEXception
driver.configure.niotMeas.multiEval.set_mo_exception(meas_on_exception = False)

Specifies whether measurement results that the CMP180 identifies as faulty or inaccurate are rejected.

param meas_on_exception:

OFF: Faulty results are rejected ON: Results are never rejected

set_np_format(npusch_format: NpuschFormat) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:NPFormat
driver.configure.niotMeas.multiEval.set_np_format(npusch_format = enums.NpuschFormat.F1)

Specifies the format of the NPUSCH.

param npusch_format:

No help available

set_nr_units(nof_ru: NofRsrcUnits) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:NRUNits
driver.configure.niotMeas.multiEval.set_nr_units(nof_ru = enums.NofRsrcUnits.NRU01)

Specifies the number of resource units allocated for the NPUSCH.

param nof_ru:

No help available

set_nrepetitions(nof_repetitions: NofRepetitions) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:NREPetitions
driver.configure.niotMeas.multiEval.set_nrepetitions(nof_repetitions = enums.NofRepetitions.NR1)

Specifies the number of NPUSCH repetitions.

param nof_repetitions:

Number of NPUSCH repetitions: 1, 2, 4, …, 512, 1024, 2048

set_nslots(nof_slots: int) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:NSLots
driver.configure.niotMeas.multiEval.set_nslots(nof_slots = 1)

Configures the length of the captured sequence of slots.

param nof_slots:

No help available

set_plc_id(phs_layer_cell_id: int) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:PLCid
driver.configure.niotMeas.multiEval.set_plc_id(phs_layer_cell_id = 1)

Specifies the physical layer cell ID.

param phs_layer_cell_id:

No help available

set_repetition(repetition: Repeat) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:REPetition
driver.configure.niotMeas.multiEval.set_repetition(repetition = enums.Repeat.CONTinuous)

Specifies the repetition mode of the measurement. The repetition mode specifies whether the measurement is stopped after a single shot or repeated continuously. Use CONFigure:..:MEAS<i>:…:SCOunt to determine the number of measurement intervals per single shot.

param repetition:

SINGleshot: Single-shot measurement CONTinuous: Continuous measurement

set_sc_spacing(sub_carr_spacing: SubCarrSpacing) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:SCSPacing
driver.configure.niotMeas.multiEval.set_sc_spacing(sub_carr_spacing = enums.SubCarrSpacing.S15K)

Selects the subcarrier spacing.

param sub_carr_spacing:

3.75 kHz or 15 kHz

set_scondition(stop_condition: StopCondition) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:SCONdition
driver.configure.niotMeas.multiEval.set_scondition(stop_condition = enums.StopCondition.NONE)

Qualifies whether the measurement is stopped after a failed limit check or continued. SLFail means that the measurement is stopped and reaches the RDY state when one of the results exceeds the limits.

param stop_condition:

NONE: Continue measurement irrespective of the limit check SLFail: Stop measurement on limit failure

set_timeout(timeout: float) None[source]
# SCPI: CONFigure:NIOT:MEASurement<Instance>:MEValuation:TOUT
driver.configure.niotMeas.multiEval.set_timeout(timeout = 1.0)

Defines a timeout for the measurement. The timer is started when the measurement is initiated via a READ or INIT command. It is not started if the measurement is initiated manually. When the measurement has completed the first measurement cycle (first single shot) , the statistical depth is reached and the timer is reset. If the first measurement cycle has not been completed when the timer expires, the measurement is stopped. The measurement state changes to RDY. The reliability indicator is set to 1, indicating that a measurement timeout occurred. Still running READ, FETCh or CALCulate commands are completed, returning the available results. At least for some results, there are no values at all or the statistical depth has not been reached. A timeout of 0 s corresponds to an infinite measurement timeout.

param timeout:

No help available

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.configure.niotMeas.multiEval.clone()

Subgroups