All
SCPI Command :
FETCh:NIOT:MEASurement<Instance>:MEValuation:SEMask:MARGin:ALL
- class AllCls[source]
All commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class FetchStruct[source]
Response structure. Fields:
Reliability: int: ‘Reliability indicator’
Out_Of_Tolerance: int: Out of tolerance result, i.e. percentage of measurement intervals of the statistic count for spectrum emission measurements exceeding the specified spectrum emission mask limits.
Margin_Curr_Neg: List[float]: Comma-separated list of 12 margin results For the current trace, area 1 to 12, negative frequency offsets
Margin_Curr_Pos: List[float]: Comma-separated list of 12 margin results For the current trace, area 1 to 12, positive frequency offsets
Margin_Avg_Neg: List[float]: Comma-separated list of 12 margin results For the average trace, area 1 to 12, negative frequency offsets
Margin_Avg_Pos: List[float]: Comma-separated list of 12 margin results For the average trace, area 1 to 12, positive frequency offsets
Margin_Min_Neg: List[float]: Comma-separated list of 12 margin results For the maximum trace, area 1 to 12, negative frequency offsets
Margin_Min_Pos: List[float]: Comma-separated list of 12 margin results For the maximum trace, area 1 to 12, positive frequency offsets
- fetch() FetchStruct[source]
# SCPI: FETCh:NIOT:MEASurement<Instance>:MEValuation:SEMask:MARGin:ALL value: FetchStruct = driver.niotMeas.multiEval.seMask.margin.all.fetch()
Returns spectrum emission mask margin results. A negative margin indicates that the trace is located above the limit line, i.e. the limit is exceeded. Results are provided for the current, average and maximum traces. For inactive areas, NCAP is returned.
- return: